TZD-2U type integrated vibration transmitter can be used in monitoring vibration severity.

TZD-2U type integrated vibration transmitter
I. Description:
TZD-2U type integrated vibration transmitter is mainly used in measuring vibration velocity. Its output form is 4mA~20mA standard current. It can be used in monitoring and protecting centrifugal pump, reciprocating compressor, centrifuge, cooling tower, industrial fan, motor, gas turbine, etc.
II. Technical parameters
● Measuring range
Vibration amplitude: *0~200um; 0~500um; 0~1000um
vibration severity: 0~10.0mm/s; *0~20.0mm/s; 0~50.0mm/s
1. Frequency response: 5 ~ 1000 Hz
2. Natural frequency of vibration: 10Hz
3. Output current: 4~20mA
4. Output impedance: ≤500Ω
5. Working voltage: DC24V
6. Connection mode: two-wire (DC24V power supply and 4~20mA use 2 wires) or three-wire (ground, power supply, output)
7. Maximum acceleration: 10g
8. Direction of measurement: vertical or horizontal
9. Operating environment: temperature -40℃~85℃ Relative humidity ≤90%
10. Size: φ45×80 (mm)
11. Weight: about 450g
12. Mounting thread: M16×1.5
III. Installation
1 Installation site: it is mounted on oscillation point vertically or horizontally.
IV. Model selection
(1) TZD-2U-W-A□
Measurement range:A□: 1-0~200um; 2-0~500um; 3-0~1000um (Vibration amplitude)
(2) TZD-2U-L-A□
Measurement range: A□: 1-0~10.0mm/s; 2-0~20.0mm/s; 3-0~50.0mm/s (vibration severity)

|