WSF Metal Tube Float Flowmeter
Introduction
Metal tube float flowmeter, also known as the “metal tube rotameter”, is a measuring instrument commonly used in the industrial automation process management to measure the variable area flow. Being featured with characteristics of small size, wide application range, convenient usage, etc., it is designed for measuring the flows of liquids, gases and steam, especially applicable for measurement of low flow speed and small flow rate.
Over the years, with its excellent property and reliability as well as preferable cost performance, the metal tube float flowmeter has been applied widely in a variety of industries, such as the petrochemical engineering, iron and steel, electric power, metallurgy, light industry, food, pharmacy, water treatment, etc.
Features
◆Designed for measurement of small caliber and low-speed medium
◆With reliable performance, few maintenance and long service life
◆Low requirement for the straight tube section
◆Widely measure ratio: 10:1
◆Dual-line display, instantaneous/ cumulative flow rates displayed at the field
◆With a keyboard on the indictor for convenient operation and setting
◆All in metal construction, designed for measuring corrosive medium of high temperature,
high pressure and strong
◆Non-contact magnetic coupling transmission
◆Applicable for inflammable and explosive occasion
◆Optional charging modes: DC power supply or battery power
◆With the functions of data recovery, data backup and power failure protection
◆Multiple parameters calibrating function
Specifications
Range of flow
|
Liquid :1.0~150000L/h
|
Gas:0.03~4000m3/h
|
Measure Ratio
|
10∶1,20∶1(special)
|
Precision
|
Grade 1.5, Grade 1.0 (special)
|
Pressure rating
|
DN15~DN50:4.0MPa;DN80~DN200:1.6MPa
|
DN15~DN50:25MPa;DN80~DN200:16MPa
|
Medium temperature
|
Standard:-80℃ ~+200℃ ,PTFE: 0℃ ~+85℃,high temperature:400℃
|
Power supply
|
Standard: 24VDC(12~36VDC); AC type: 85~265VAC 50Hz; Battery type:3.6V@4AH
|
Output signal
|
Collector open circuit output(max 100mA@30VDC internal impedance 100Ω
|
Relay output(max 5A@250VAC)
|
Environmental temperature
|
Liquid crystal type:-30℃ ~85℃
Pointer type: -40℃ ~120℃
|
Storage requirement
|
Temperature:-40℃ ~85℃ humidity:≤85%
|
Connection mode
|
Flange connecting. Flange standard :GB/T9119-2000; User’s appointment allowed
|
Cable interface
|
M20×1.5
|
Housing protection grade
|
Ip65
|
Mark of explosion-proof
|
Intrinsic safety type:ExiaIICT6 explosion-proof type:ExdIICT6
|
Pressure loss
|
7kPa~70kPa
|
Viscosity of medium
|
DN15:η<5mPa.s DN25:η<250mPa.s DN50~DN150:η<300mPa.s
|
Contact material
|
R1:304,1Cr18Ni9Ti; Ro:316,0Cr18Ni12Mo2Ti; RL:316L,00Cr17Ni14Mo2Ti;
|
Ti:Titanium alloy; Rp:PTFE lining
|
Product selection
WSF
|
|
Measurement
tube structure
|
0:Flow in from below and out from above
|
1:Flow in from below and out horizontally from above
|
2:Flow in horizontally from below and out horizontally from above
|
3R:Flow in from the right and out from the left
|
3L:Flow in from the left and out from the right
|
Material
|
R0:316,0Cr18Ni12Mo2Ti
|
R1:304,1Cr18Ni9Ti
|
RP:PTFE lining
|
Ti:Titanium alloy
|
RL:316L,00Cr17Ni14Mo2Ti
|
Pipeline caliber
|
DN15, DN25, DN50, DN80, DN100, DN150, DN200
|
Additional structure
|
T:Jacket type
|
Z:Damping type
|
G:High temperature type
|
Y:High pressure type
|
Indicator
|
M1
|
M2
|
M3
|
Power supply mode
|
No
|
A:220VAC,4-20mAoutput,with backlight
|
B:Battery powered, without output
|
C:24VDC,4-20mA output,without backlight
|
D:24VDC,4-20mA output,with backlight
|
Explosion proof grade
|
No
|
I:ExiaⅡCT5 Square shell
|
D:ExiaⅡBT4 Round shell
|
Output mode
|
No
|
K1:Upper limit alarm or one pulse output
|
K2:Lower limit alarm or one pulse output
|
K3:Upper and lower limit alarm or two-way pulse output
|
|